hga010手机版下载·(中国区)官方网站hga010手机版下载

Product

Product

Smart High Side Switch

The NSE34xxx/NSE35xxx series high-side switches are designed for driving various traditional resistive, inductive, and halogen lamp loads in systems like automotive BCMs, while also being well-suited for handling large capacitive loads commonly found in first and second-level distribution in Zonal Control Units (ZCUs). These series offer options for 1, 2, or 4 channels and are available in HSSOP-16/HSSOP-14 packages, with an Rds(on) range from 8mΩ to 140mΩ. The chips feature precise current sensing, ideal for fault diagnosis, protection, and real-time monitoring of load currents. Additionally, the NSE34xxx/NSE35xxx series incorporate comprehensive protection mechanisms, including overcurrent/short-circuit protection, overtemperature protection, overvoltage protection, ground and power loss protection, reverse polarity protection, and open-load detection.The NSE34xxx and NSE35xxx series products are AEC-Q100 qualified and certified to AEC-Q100-012 level A, ensuring over a million cycles of short-circuit and overcurrent protection.

View All Products

  • Ambient Temperature
    -40°C~125°C
  • Number of Channels
    1CH
    2CH
    4CH
  • MOS Impedance
    8mΩ
    10mΩ
    12mΩ
    25mΩ
    50mΩ
    140mΩ
  • Package
    HSSOP-16
    HSSOP-14

show 27 devices

Part Number ECAD Model Ambient Temperature Number of Channels MOS Impedance Protection Feature Application Package
NSE34025Q
-40℃~125℃
4CH
25mΩ
Overcurrent protection
Short-circuit protection
Overvoltage protection
Over-temperature protection
Lost ground protection
Lost power protection
Reverse polarity protection
Open circuit diagnosis
Support inductive loads
BCM
ZCU
HSSOP-16
NSE34050Q
-40℃~125℃
4CH
50mΩ
Overcurrent protection
Short-circuit protection
Overvoltage protection
Over-temperature protection
Lost ground protection
Lost power protection
Reverse polarity protection
Open circuit diagnosis
Support inductive loads
BCM
ZCU
HSSOP-16
NSE34140Q
-40℃~125℃
4CH
140mΩ
Overcurrent protection
Short-circuit protection
Overvoltage protection
Over-temperature protection
Lost ground protection
Lost power protection
Reverse polarity protection
Open circuit diagnosis
Support inductive loads
BCM
ZCU
HSSOP-16
NSE34050D
-40℃~125℃
2CH
50mΩ
Overcurrent protection
Short-circuit protection
Overvoltage protection
Over-temperature protection
Lost ground protection
Lost power protection
Reverse polarity protection
Open circuit diagnosis
Support inductive loads
BCM
ZCU
HSSOP-16
NSE34050S
-40℃~125℃
1CH
50mΩ
Overcurrent protection
Short-circuit protection
Overvoltage protection
Over-temperature protection
Lost ground protection
Lost power protection
Reverse polarity protection
Open circuit diagnosis
Support inductive loads
BCM
ZCU
HSSOP-16
NSE34140D
-40℃~125℃
2CH
140mΩ
Overcurrent protection
Short-circuit protection
Overvoltage protection
Over-temperature protection
Lost ground protection
Lost power protection
Reverse polarity protection
Open circuit diagnosis
Support inductive loads
BCM
ZCU
HSSOP-16
NSE34140S
-40℃~125℃
1CH
140mΩ
Overcurrent protection
Short-circuit protection
Overvoltage protection
Over-temperature protection
Lost ground protection
Lost power protection
Reverse polarity protection
Open circuit diagnosis
Support inductive loads
BCM
ZCU
HSSOP-16
NSE34025D
-40℃~125℃
2CH
25mΩ
Overcurrent protection
Short-circuit protection
Overvoltage protection
Over-temperature protection
Lost ground protection
Lost power protection
Reverse polarity protection
Open circuit diagnosis
Support inductive loads
BCM
ZCU
HSSOP-16
NSE34025S
-40℃~125℃
1CH
25mΩ
Overcurrent protection
Short-circuit protection
Overvoltage protection
Over-temperature protection
Lost ground protection
Lost power protection
Reverse polarity protection
Open circuit diagnosis
Support inductive loads
BCM
ZCU
HSSOP-16
NSE34012D
-40℃~125℃
2CH
12mΩ
Overcurrent protection
Short-circuit protection
Overvoltage protection
Over-temperature protection
Lost ground protection
Lost power protection
Reverse polarity protection
Open circuit diagnosis
Support inductive loads
BCM
ZCU
HSSOP-16
NSE34012S
-40℃~125℃
1CH
12mΩ
Overcurrent protection
Short-circuit protection
Overvoltage protection
Over-temperature protection
Lost ground protection
Lost power protection
Reverse polarity protection
Open circuit diagnosis
Support inductive loads
BCM
ZCU
HSSOP-16
NSE34008D
-40℃~125℃
2CH
8mΩ
Overcurrent protection
Short-circuit protection
Overvoltage protection
Over-temperature protection
Lost ground protection
Lost power protection
Reverse polarity protection
Open circuit diagnosis
Support inductive loads
BCM
ZCU
HSSOP-16
NSE34008S
-40℃~125℃
1CH
8mΩ
Overcurrent protection
Short-circuit protection
Overvoltage protection
Over-temperature protection
Lost ground protection
Lost power protection
Reverse polarity protection
Open circuit diagnosis
Support inductive loads
BCM
ZCU
HSSOP-16
NSE35120DA
-40℃~125℃
2CH
60mΩ
Overcurrent protection
Short-circuit protection
Overvoltage protection
Over-temperature protection
Lost ground protection
Lost power protection
Reverse polarity protection
Open circuit diagnosis
Support inductive loads
BCM
ZCU
HSSOP-14
NSE35200DA
-40℃~125℃
2CH
60mΩ
Overcurrent protection
Short-circuit protection
Overvoltage protection
Over-temperature protection
Lost ground protection
Lost power protection
Reverse polarity protection
Open circuit diagnosis
Support inductive loads
BCM
ZCU
HSSOP-14
NSE35040DA
-40℃~125℃
2CH
20mΩ
Overcurrent protection
Short-circuit protection
Overvoltage protection
Over-temperature protection
Lost ground protection
Lost power protection
Reverse polarity protection
Open circuit diagnosis
Support inductive loads
BCM
ZCU
HSSOP-14
NSE35040SA
-40℃~125℃
1CH
20mΩ
Overcurrent protection
Short-circuit protection
Overvoltage protection
Over-temperature protection
Lost ground protection
Lost power protection
Reverse polarity protection
Open circuit diagnosis
Support inductive loads
BCM
ZCU
HSSOP-14
NSE35080DA
-40℃~125℃
2CH
20mΩ
Overcurrent protection
Short-circuit protection
Overvoltage protection
Over-temperature protection
Lost ground protection
Lost power protection
Reverse polarity protection
Open circuit diagnosis
Support inductive loads
BCM
ZCU
HSSOP-14
NSE35012DA
-40℃~125℃
2CH
12mΩ
Overcurrent protection
Short-circuit protection
Overvoltage protection
Over-temperature protection
Lost ground protection
Lost power protection
Reverse polarity protection
Open circuit diagnosis
Support inductive loads
BCM
ZCU
HSSOP-14
NSE35012SA
-40℃~125℃
1CH
12mΩ
Overcurrent protection
Short-circuit protection
Overvoltage protection
Over-temperature protection
Lost ground protection
Lost power protection
Reverse polarity protection
Open circuit diagnosis
Support inductive loads
BCM
ZCU
HSSOP-14
NSE35020DA
-40℃~125℃
2CH
12mΩ
Overcurrent protection
Short-circuit protection
Overvoltage protection
Over-temperature protection
Lost ground protection
Lost power protection
Reverse polarity protection
Open circuit diagnosis
Support inductive loads
BCM
ZCU
HSSOP-14
NSE35030DA
-40℃~125℃
2CH
12mΩ
Overcurrent protection
Short-circuit protection
Overvoltage protection
Over-temperature protection
Lost ground protection
Lost power protection
Reverse polarity protection
Open circuit diagnosis
Support inductive loads
BCM
ZCU
HSSOP-14
NSE35010DA
-40℃~125℃
2CH
10mΩ
Overcurrent protection
Short-circuit protection
Overvoltage protection
Over-temperature protection
Lost ground protection
Lost power protection
Reverse polarity protection
Open circuit diagnosis
Support inductive loads
BCM
ZCU
HSSOP-14
NSE35010SA
-40℃~125℃
1CH
10mΩ
Overcurrent protection
Short-circuit protection
Overvoltage protection
Over-temperature protection
Lost ground protection
Lost power protection
Reverse polarity protection
Open circuit diagnosis
Support inductive loads
BCM
ZCU
HSSOP-14
NSE35008DA
-40℃~125℃
2CH
8mΩ
Overcurrent protection
Short-circuit protection
Overvoltage protection
Over-temperature protection
Lost ground protection
Lost power protection
Reverse polarity protection
Open circuit diagnosis
Support inductive loads
BCM
ZCU
HSSOP-14
NSE35008SA
-40℃~125℃
1CH
8mΩ
Overcurrent protection
Short-circuit protection
Overvoltage protection
Over-temperature protection
Lost ground protection
Lost power protection
Reverse polarity protection
Open circuit diagnosis
Support inductive loads
BCM
ZCU
HSSOP-14
NSE35008SP
-40℃~125℃
1CH
8mΩ
Overcurrent protection
Short-circuit protection
Overvoltage protection
Over-temperature protection
Lost ground protection
Lost power protection
Reverse polarity protection
Open circuit diagnosis
Support inductive loads
BCM
ZCU
HSSOP-14

For more product information, please contact us.

hga010手机版下载